CBCYV - SEAL GRIP STAIN BLOCK PR, 17-21 (110193E)

  • MSDS: CBCYV
  • Manufacturer: PPG INDUSTRIES INC
  • Product Name: SEAL GRIP STAIN BLOCK PR, 17-21 (110193E)
  • National Stock Number: 8010-00N065459
Product Identification

Product ID:SEAL GRIP STAIN BLOCK PR, 17-21 (110193E)
MSDS Date:11/09/1993
FSC:8010
NIIN:00N065459
MSDS Number: CBCYV

Responsible Party
PPG INDUSTRIES INC
4325 ROSANNA DR
ALLISON PARK, PA 15101
US

Emergency Phone: 304-843-1300

Info Phone: 412-492-5555

Cage: DO542

Contractor
PPG INDUSTRIES INC. COATINGS & RESINS GP
9 ALLISON PARK, PA 15101

Telephone: 412-492-5555

Cage: DO542

Ingredients

ZINC OXIDE (SARA 313) (CERCLA)

CAS: 1314-13-2

RTECS: ZH4810000

Fraction By Weight: 1-2%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


1); (CALCIUM CARBONATE)

CAS: 471-34-1

RTECS: FF9335000

Fraction By Weight: 5-10%

OSHA PEL N/K

ACGIH TLV: N/K


TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (MAGNESIUM

CAS: 14807-96-6

RTECS: WW2710000

Fraction By Weight: 5-10%

OSHA PEL 20 MPPCF Z-3

ACGIH TLV: 2 MG/M3 RDUST


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 10-15%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


WATER; (TAP WATER)

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 10-15%

OSHA PEL N/K

ACGIH TLV: N/K


ETHYLENE GLYCOL (SARA 313) (CERCLA)

CAS: 107-21-1

RTECS: KW2975000

Fraction By Weight: 1-2%

OSHA PEL N/K

ACGIH TLV: C 50 PPM,VAPOR

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


WATER; (DEIONIZED WATER)

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 30-35%

OSHA PEL N/K

ACGIH TLV: N/K


FILM,FORMERS, RESINS, & ADDITIVES

Fraction By Weight: 20-25%

OSHA PEL N/K

ACGIH TLV: N/K


OVEREXPOS ARE NOT EXPECTED, THERE IS NO

RTECS: 9999999ZZ


WHICH MAY CAUSE KIDNEY & LIVER DAMAGE AND WHICH HAS

RTECS: 9999999ZZ


NITRILE, NEOPRENE OR LATEX.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:HARMFUL/FATAL. EYE:CAUSES IRRIT
INDICATED BY REDNESS, ITCHING, BURNING SENSATION & VISUAL DISTURBS.
SKIN:MAY CAUSE SLIGHT IRRIT INDICATED BY DRYNESS, ITCHING,
CRACKING, BURNING, REDNESS & SWELL . INHAL:VAP & SPRAY MIST MAY BE
HARMFUL. VAP GENERATED @ ELEVATED TEMPS IRRITS EYES, NOSE & THROAT.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:CHRONIC:AVOID LONG TERM & RPTD CONT.
PROD CNTNS TITANIUM DIOXIDE. ANIMALS INHAL MASSIVE QTYS OF ING 4
DUST IN LONG-TERM STUDY DEVELOPED LUNG TUMORS. STUDIES W/HUMANS
INVOLVED IN MFR OF PIGME NT INDICATE NO INCRD RISK OF CANCER FROM
EXPOS. POTNTL FOR INHAL OF ING 4 DUSTS FROM COATING IS VERY LTD.
SINCE (ING 9)

First Aid

First Aid:INGEST:DO NOT INDUCE VOMIT. EYE:FLUSH IMMED W/PLENTY OF WATER
FOR @ LST 15 MIN. SKIN:FLUSH IMMED W/PLENTY OF WATER FOLLOWED BY
WASHING W/SOAP & WATER. INHAL:REMOVE TO FRESH AIR. APPLY ARTF RESP
& OTHE R SUPPORTIVE MEASURES AS REQ. OTHER:IF INGEST, ANY TYPE OF
OVEREXP/SYMPS OF OVEREXP OCCUR DURING/FOLLOWING USE OF PROD, CONT
POIS CTL CTR, EMER ROOM/MD IMMED; HAVE MSDS INFO AVAIL.

Fire Fighting

Flash Point Method:PMCC
Extinguishing Media:USE NATL FIRE PROT ASSOC (NFPA) CLASS B EXTINGS
(CARBON DIOXIDE, DRY CHEM/UNIVERSAL AQUEOUS FILM FORMING FOAM) (SUP
DAT)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFTIVE. WATER SPRAY MAY BE USED TO COOL CLSD
CNTNRS TO PVNT PRESS BUILD-UP & (SUPDAT)
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE OR BURST
(DUE TO BUILD-UP OF STEAM PRESSURE) WHEN EXPOSED TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:PROVIDE MAX VENT. ONLY PERS EQUIPPED W/PROPER
NIOSH/MSHA APPRVD RESP, SKIN & EYE PROT SHOULD BE PERMITTED IN
AREA. REMOVE ALL SOURCES OF IGNIT. TAKE UP SPILLED MATL W/SAWDUST,
VERMICULITE/OTHER ABSORB MATL & PLACE INTO CNTNRS FOR DISP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED AND PROTECTED FOR STORAGE OF NFPA
CLASS IIIB LIQUIDS. PROTECT FROM FREEZING.
Other Precautions:IF THIS MATERIAL IS PART OF A MULTIPLE COMPONENT
SYSTEM, READ THE MATERIAL SAFETY DATA SHEET(S) FOR THE OTHER
COMPONENT OR COMPONENTS BEFORE BLENDING AS THE RESULTING MIXTURE
MAY HAVE THE HAZARDS OF A LL ITS PARTS.

Exposure Controls

Respiratory Protection:WHERE VENTILATION IS INADEQUATE, USE A
NIOSH/MSHA APPROVED SUITABLE RESPIRATOR.
Ventilation:PROVIDE GEN DILUTION/LOC EXHST VENT IN VOL & PATTERN TO
KEEP CONC OF INGS BELOW LOWEST SUGGEST EXPOS LIMS, LEL (SUPDAT)
Protective Gloves:NITRILE, NEOPRENE OR LATEX GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER
WEAR PROT CLTHG, INCLUDING IMPERMEABLE APRON CONSTRUCTED OF (ING
11)
Work Hygienic Practices:CLEAN OR DISCARD CONTAMINATED CLOTHING AND
SHOES.
Supplemental Safety and Health
EXTING MEDIA:DESIGNED TO EXTING NFPA CLASS IIIB LIQ FIRES. FIRE FIGHT
PROC:POSS AUTOIGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT. IF WATER IS
USED, FOG NOZZS ARE PREF. HAZ DECOMP PRODS:MONOXIDE, ZINC OXID E.
VENT:IN FIRE/EXPLO SECTION BELOW STATED LIM, & REMOVE DECOMP PRODS
DURING WELDING/FLAME CUTTING.

Chemical Properties

Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:17.2
Vapor Density:HVR/AIR
Spec Gravity:1.29
Evaporation Rate & Reference:33 (BUAC=100)
Solubility in Water:58.1%
Appearance and Odor:VISCOUS LIQ W/ODOR CHARACTACTERISTIC OF CHEMICAL
FAMILY & SOLVS LISTED IN INGS.
Percent Volatiles by Volume:62.06

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG ALKALIES, STRONG MINERAL ACIDS, OR STRONG
OXIDIZING AGENTS.
Stability Condition to Avoid:AVOID CONTACT WITH STRONG ALKALIES, STRONG
MINERAL ACIDS, OR STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products:MAY PRDCE HAZ DECOMP PRODS WHEN
HEATED. WELDING, BRAZING/FLAME CUTTING MAY PRDCE FUMES
INCLUDING:CARBON (SUPP DATA)

Disposal

Waste Disposal Methods:WASTE MATERIAL MUST BE DISPOSED OF IN ACCORDANCE
WITH FEDERAL, STATE, PROVINCIAL AND LOCAL ENVIRONMENTAL CONTROL
REGULATIONS. EMPTY CONTAINERS SHOULD BE RECYCLED OR DISPOSED OF
THROUGH AN APPROVED WAS TE MANAGEMENT FACILITY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.